Yueqing CNAOB Electric Co., Ltd.

home products HIGH VOLTAGE SWITCH FN16A-12 Series Indoor HIGH VOLTAGE Load Switch 12KV WITH FUSE WITHOUT FUSE

FN16A-12 Series Indoor HIGH VOLTAGE Load Switch 12KV WITH FUSE WITHOUT FUSE

Product Details:

Max. Voltage 12KV
Max. Current 400A
Place of Origin Zhejiang, China (Mainland)

Payment & Shipping Terms:

Payment Terms: L/C,T/T,Western Union

Detailed Product Description


FN16A-12 Series Indoor HIGH VOLTAGE Load Switch 12KV WITH FUSE WITHOUT FUSE used in the network of AC 50Hz,6KV or 12KV

Technical parameter
1.FN16A-12D/630 type load switch with -fuse box technical parameter(please see the table)1
NumberNameUnitParameter
1Rated voltage KV12
2Rated frequency Hz50
3Rated current A630
4Rated power load switch-off current A630
5Rated closed switch-off current A630
65% Rated power load switch-off current A31.5
7Rated cable charging switch-off current A10
8Rated capcity switch-off curerent A400
9Rated switch-off current of no-load transformer  1600VK Acurrent of no-load transformer
101min power frequency withstand voltagevalue(to ground interphase vacuum break/isolation break)KV42/48
11full ware lighting impulse resisting voltage peak to ground interphase vacuum break/isolation break KV75/85
12Rated short-time withstand current heat-steadilyKVIS20/3
13Rated peak withstand current machine-steadilyKV50
14Rated short-circuit controlly current KV50
15Rated current breaking times 10000
16Mechanical life 10000
17Alltomatic striking and trinding cumulation thickness mm3
18Switch on-and-off operating mement 120240
19Rated swictch-on operate voltage current V/A220/0.5
20Rated switch-off operate voltage/current V/A220/3
2.FN16A-12RD/200-31.5 type load switch with-fuse box technical parameter(please see the table2)
NumberNameUnitParameter
1Rated voltage(the highest working voltage)KV12
2Rated frequency Hz50
3The Max.Rated current of fuse box A200
4Rated transfer current A3150
5Switch-off time of fuse box stroking switch ms310+5
6Rated short-circuit switch-off current prospeiltive peakKA31.5
7Rated short-circuit controlly current prospeltive peakKA80
8

1min Power frequency withstand voltage(value )(to earth.interphase/isolation break)

KV42/48
9full wave lighting impulse resisting voltage (peak )(to earth.interphase/isolating break) KV75/85
10Fues box striker output energy J2-5
3.Isolating switch technical parameter(please see the table3)
NumberNameUnitParameter
1Three phase switch-on position not the same period mm≤3
2Each phase switch-on posetion not the same period mm≤2
3The front pressure of contact N200±20
4The minimum distance between static contuct and the end of isolate pole of contrct mm
5Main return circuit resistance betwen static contanct and upper uper support υΩ≤100
4.FN16A/12RD/200-31.5 type switch with fuse with fuse box technical prameter (please see the table4).
TypeRated voltage Fuse box rated current(A) Rated switch-off current(kA) Fuse body rated current(A)
SDLAJ,XRNT1240506.3,10,16,20,25,31.5,40
SDLAJ,XRNT10050,63,71,80,100
SDLAJ,XRNT125125
SIBA1220040160,200
5.Vacuum are room technical parameter(please see the table5)
NumberNameUnitParameter
1Contact distance Mm≤8+10
2Ultra traved mm≤5+10
3Avarage switch-off speed m/s06±0.2
4Average switch-off speed m/s1±0.2
5Therr-phase contact switch on-and-off not thesame period ms≤2
6Contact switch-on jump time ms≤2
7Distance between charged bodies and between phase and ground mm≥125
8Main return circuit resistance between upper and lower support υΩ≤60
6.Earth switch technical parameter(please see the table6)
NumberNameUnitParameter
1The front pressure of contact N200±200
2The squary of touching  2/3
3Three phase switch-on position not the same period mm≤3
4Each phase switch-on poseition gradient mm≤1.5
5The speed of switch-on m/s≥2.5

FN16A-12 Series Indoor HIGH VOLTAGE Load Switch 12KV WITH FUSE WITHOUT FUSE FN16A-12 Series Indoor HIGH VOLTAGE Load Switch 12KV WITH FUSE WITHOUT FUSE

Send your message to this supplier
« Prev Product ... 8 9 10 11 12 13 14 ... Next Product »

Other Products from this Supplier

Company Info

Yueqing CNAOB Electric Co., Ltd.
[China (Mainland)]
[Verified Member]

City: Wenzhou
Province/State: Zhejiang
Country/Region : China (Mainland)

Business Type:Manufacturer

View Contact Details

Email this page Bookmark this page Print this Page